Comparative study between cuff sizes in the determination of systolic blood pressure, by non-invasive methods in anesthetized dogs

Estudo comparativo entre a numeração de manguitos utilizados na determinação da pressão arterial sistólica por métodos não invasivos em cães anestesiados

Autores

DOI:

https://doi.org/10.53660/CLM-3315-24H38

Resumo

The measurement of systolic blood pressure (SBP) is a variable of paramount importance in clinical routine, obtained and measured according to published guidelines for dogs. The study evaluated the influence of cuff size on the determination of systolic blood pressure (SBP) values in dogs, comparing two non-invasive methods. Eighteen healthy dogs of different breeds and ages were used, clinically evaluated and undergoing elective surgeries. SBP was measured using vascular Doppler and high-definition oscillometric methods during the anesthetic period, using both ideal-sized cuffs and smaller cuffs. The dogs were divided into groups, Group 1 composed of dogs with ideal cuff no. 2, Group 2 dogs with ideal cuff no. 3 and Group 3 ideal cuff no The results showed that smaller cuffs significantly overestimated the mean SBP values compared to the ideal cuff values, regardless of the method used. It was concluded that cuffs with a lower than ideal number overestimate SBP values in anesthetized dogs, regardless of the non-invasive method used.

Downloads

Não há dados estatísticos.

Referências

ACIERNO, M. J.; BROWN, S.; COLEMAN, A. E.; JEPSON, R. E.; PAPICH, M.; STEPIEN, R. L.; SYME, H. M. ACVIM consensus statement: Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats. Journal of Veterinary Internal Medicine, v.32, p.1803-1822, 2018.

ARCURY, E.A.M.; ARAÚJO, T.L.; VEIGA, E.V.; OLIVEIRA S.M.J.V.; LAMAS, J.T.; SANTOS, J.L.F. Blood pressure measurement and the scientific production of Brazilian nurses. Journal of the USP School of Nursing, v. 41, n. 2, p. 202-298, 2007.

BALA, M.; TURKAR, S.; SAINI, N.; RANDHAWA, C.S.; KASHYAP, N.; High Definition Oscillometric Blood Pressure Measurement in Apparently Healthy Dogs: A Clinical Study. Journal of Animal Research, v.11, n. 4, p. 637-641, 2021

BOSIACK, A. P.; MANN, F. A.; DODAM, J. R.; WAGNER-MANN, C. C.; BRANSON, K. R. Comparison of ultrasonic doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs. Journal of Veterinary Emergencial and Critical Care. v.20, n.2, p.207-215, 2010.

CARR, A. Measuring blood pressure in dogs and cats. Vet. Med. v. 2, p.135-144, 2001.

CHETBOUL, V.; TISSIER, R.; GOUNI, V.; de ALMEIDA, V.; LEFEBVRE, H.P.; CONCORDET, D.; JAMET, N.; SAMPEDRANO, C. C.; SERRES, F.; POUCHELON, J.L. Comparison of doppler ultrasonography and high-definition oscillomery for blood pressure measurements in healthy awake dogs. American Journal of Veterinary Reserch, v.71, n.7, p. 766-772, 2010.

DURHAM, H. E. Arterial Blood Pressure Measurement. Vetfolio – Veterinary Technician. Acesso em: https://www.vetfolio.com/learn/article/arterial-blood-pressure-measurement. 2019.

GARCIA, J. L. Just Ask the Expert: Advice on proper blood pressure cuff size and placement. Acesso em: https://www.dvm360.com/view/just-ask-expert-advice-proper-blood-pressure-cuff-size-and-placement. 2011.

HABERMAN C. E.; KANG, C. W.; MORGAN, J. D.; BROWN, S. A. Evaluation of oscillometric and doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs. The Canadian Journal of Veterinary Research, v. 70, p. 211-217, 2006.

HENIK, R. A.; BROWN, S. A. Systemic Hipertension. In: P., Tilley L.. Manual of Canine and Feline Cardiology. 4. ed. Canada: Saunders Elsevier, Cap. 14. p. 277-286, 2008.

HENIK, R. A.; DOLSON, M. K.; WENHOLZ, L. J. How to obtain a blood pressure measurement. Clinical Techniques in Small Animal Practice. v. 20, p. 144-150, 2005.

OLIVEIRA, D.R.; MALLET, T.O.; FERRONATTO, J.V.B.; MONTEIRO, E.R. Systolic blood pressure in anesthetized dogs - agreement between measurements by two non-invasive methods. Acta Scientiae Veterinariae. v.49, p. 1841 a 184,2021

PEREIRA-NETO, G. B.; BRUNETTO, M. A.; CHAMPION, T.; ORTIZ, E. M. G.; CARCIOFI, A. C.; CAMACHO, A. A. Assessment of systemic blood pressure in obese dogs: comparison between oscillometric and ultrasonic doppler methods. Brazilian Veterinary Research, v. 34, p. 87-91, 2014.

RONDEAU, D. A.; MACKALONIS, M. E.; HESS, R. E. Effect of body position on indirect measurement of systolic arterial blood pressure in dogs. Journal of the American Veterinary Medical Association, v. 242, n. 11, p. 1523-1527, 2013.

SELISKAR, A.; ZRIMSEK, P.; SREDENSEK, J.; D PETRIC, A.; Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs Veterinary Anaesthesia and Analgesia, 2012

SMITH, L. New AHA recomendations for blood pressure measurement. American Family Physician, v. 72, n. 7, p. 1391-1398, 2005.

STEPIEN, R. L. Blood pressure measurement in dogs and cats. In Practice, v.22, p.136-145, 2000.

VALTONEN, M. H.; ERIKSSON, L. M. The effect of cuff width on acuracy of indirect measurement of blood pressure in dogs. Research in Veterinary Science, n. 2, p. 358-362, 1970.

WADDELL, L. S. Direct Blood Pressure Monitoring. Clinical Techniques in Small Animal Practice, v. 15, n.3, p.111-118, 2000.

WAGNER, A. E.; WRIGHT, B. D.; HELLYER, P. W. Myths and misconceptions in small animal anestesia. Journal of the American Veterinary Medical Association, v. 223, n.10, p.1426-1432, 2003.

WERNICK, M.; DOHERR, M.; HOWARD, J.; FRANCEY, T.; Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines, Journal of Small Animal Practice, v.51, p. 318–324, 2010

Downloads

Publicado

2024-04-27

Como Citar

Franco, R. . ., Nakamura , T. Y. ., Pereira, E. R. de O. ., Carratore, C. R. D. ., Teixeira , D. B. ., Porto, . C. D. ., Repetti, C. F. ., Manhoso, F. F., & Bueno, P. C. dos S. . (2024). Comparative study between cuff sizes in the determination of systolic blood pressure, by non-invasive methods in anesthetized dogs: Estudo comparativo entre a numeração de manguitos utilizados na determinação da pressão arterial sistólica por métodos não invasivos em cães anestesiados. Concilium, 24(8), 119–132. https://doi.org/10.53660/CLM-3315-24H38

Edição

Seção

Artigos